The Yunnan Provincial Highway Bureau Staff and Workers University purchased the Taiwan Komatsu company's production and training in 1996. In the month of 999, the excavator had a malfunction of the generator rotor stuck to the drive belt. The demolition of the motor revealed that the rolling bearings that supported the rotor were damaged and replaced the same type of bearings. After the engine was installed, the generator still did not generate electricity.
The generator was dismantled and examined in detail. It was found that the structure of the alternator was basically similar to that of the domestic alternator. The unique feature was that an integrated circuit regulator with a small volume was installed on the heat sink of the generator to form an integral whole. . The advantages of this structural design are the high precision of the voltage adjustment, the durability of the shock-proof volume, and the simple wiring. At present, this type of structure has been widely used on a generator of a passenger car engine to test the generator on a test bench with universal use. The field winding of the stator winding of the silicon tube has no short-circuit breaking phenomenon and the resistance value is within the normal range. The rotor rotates. normal. The brush is working properly. It is diagnosed as damage to the integrated circuit regulator.
What causes the damage to the IC regulator? Because the alternator's output current and speed are higher than traditional DC generators, it generates much more transient energy than a DC generator. Semiconductor devices are very sensitive to transient voltages. When the transient voltage or overvoltage reaches a constant value, the semiconductor device is easily broken down and damaged.
In the excavator electrical system, transient voltage and overvoltage are generated mainly due to the following conditions. In view of the working conditions of the excavator, one method of removing the fault is to replace the generator because the Komatsu excavator parts seller has no off-the-shelf supply and quote Higher, in time. Economically it is not allowed; it is to replace the integrated circuit regulator. However, in the local auto and engineering machinery parts market there is no sales of regulators of the same type; external domestic electromagnetic regulators are used instead of integrated circuit regulators. According to the output characteristic 2 of the alternator, the alternator has the self-protection ability of limiting the current automatically, and no additional current limiter is needed. Only one voltage adjustment relay is required, and the relay type regulator has strong surge resistance. Voltage capability. From the theoretical analysis of this method is simple and feasible.
After performing paired tests on several domestic voltage regulators on an electrical test bench, the final decision was to use the 5021 voltage regulator, which is a single-stage voltage regulator with an arc extinguishing circuit and a temperature compensation device.
The most current rated current method is as follows: first cut off the connecting end of the integrated circuit regulator and the generator, and direct the output characteristics of the magnetic field direct 2 alternator to the magnetic field terminal of the generator, and then assemble the generator. After the alternator regulator is connected with a wire on the test bench, a pairing test is performed to measure the no-load full-load speed under the rated voltage of the generator, so as to judge whether the generator is working properly and whether the regulator meets the requirements. When the battery is charged, the lead connected to the battery is suddenly disconnected, or in the absence of the battery, the other load is abruptly disconnected. When the alternator is externally supplied, if the load is suddenly disconnected, the current in the stator winding suddenly decreases. Small, producing very small, large capacity, transient energy generated by disconnecting the load is absorbed by the battery, so does not produce a very high instantaneous spike voltage. However, if the generator is charging the battery and supplying other loads, the connection between the generator and the battery is suddenly interrupted, or when the load is abruptly disconnected without the battery, the generator armature induction coil will A very high transient overvoltage is generated, and there is a risk that the electronic components in the generator and the regulator will be broken down. This is confirmed by the external characteristics of the alternator. The larger the load that is thrown away, the higher the speed of the generator; the faster the disconnection speed, the greater the amplitude of the transient voltage generated and the longer the decay time, so the connection between the alternator and the battery must be reliable.
The sudden change of the magnetic field current causes the transient winding of the alternator. Since the power switch is turned to the off position and the battery is suddenly interrupted, an exponentially decaying negative pulse voltage is generated. The amplitude is as high as 50100 due to the large time constant of the excitation circuit. The decay time can reach up to 200 tubes and the electronic components in the regulator over a long period of time.
Electric equipment switching causes transients because the field construction site needs lighting at night, and excavators often work overtime at night. When the lighting is turned on and off, the generator load suddenly mutates to generate transient voltages, which can also cause pole tubes. And the electronic components in the regulator are damaged. Therefore, when using lighting fixtures, they should be opened and closed one by one.
18 Dangerous voltages are maintained, and the result of easy breakdown test results such as 1 speed current A voltage V speed current A voltage v test result shows that the generator and regulator work normally and can meet the daily power requirements of the excavator.
Finally, connect the generator and exterior regulator to the electrical system of the excavator according to the wiring method of 3, and install it. After starting the engine, the generator and electrical equipment are working properly. This clearly demonstrates that the method of replacing imported electronic devices with domestic devices has been successful.
1 Gu Yongqi, Zhao Ming. Automotive electrical and electronic equipment 1. Chongqing Chongqing University Publishing 2 Xi'an Highway College. Automotive tractor electrical and electronic equipment elbow. Beijing People's Communications Press, 1985.
20W Glue Guns Features:
1. Versatile
2. Easy
3. Quick
4. Proective Nozzle Cover
5. Trigger Flow Control
6. Bonds instantly
7. High quality
8. High temperature or low temperature
9. New design
10. With switch function
Idea for many applications. Fastening various materials such as paper, cardboard, fabric,wood, lace,trims,leather,metal,glass, tiles, rubber, ceramics and flooring etc.Ideal for hobby and household repair,DIY&craft projects.
Designed and manufactured to the highest of standards to ensure a robust and long life, we hope it provides you with many years of trouble-free, safe and reliable service.
Important Caution:
1. Before use the glue gun, check if the plug cord into electrical outlet properly;
2. When glue gun in first use, the heating element will have small smoke, it is normal situation, but the smoke will disappeared after 10 minutes;
3. After power, not for a long time in standby mode(not longer for 20 minutes), when the suspension of use, unplug first.
4. Avoid to use the glue gun under very hot or very cold environments.
5. Better not work under direct cold wind blowing, it will reduce efficiency and loss power
6. When in continuous using, do not press the trigger with great pressure, and try to squeeze out the un-melted glue, it would damage the glue gun
7. Not applicable for bonding heavy objects or objects needed strong adhesive
8. The quality of glue stick will directly influence the glue gun function and sticking objects quality;
9. If the power cord is damaged, do not replace it by yourself, must ask for professionals to replace it.
10. This tools must b e placed in its position when not in use. And storage before the tools complete cooled.
11. Be careful when using any other electrical appliance with flammable material.
12. Not applicable for a long time in the same place.
13. Do not use an explosive gas atmospheres.
14. Note that heat may be the line of sigh, combustible materials.
15. Do not leave equipment unattended when switched on.
16. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
17. Children should be supervised to ensure that they do not play with the appliance.
Using methods
1. Glue gun using voltage is 110-220V AC,50/60Hz;
2. Tip gun forward on stand and place a piece of cardboard under the nozzle
3. Use 7-8mm (mini trigger glue gun), 11-12(big trigger glue gun), insert glue sticks through
tunnel at back of gun
4. After power, wait for 5-10 minutes to allow glue to soften
After glue softens, squeeze trigger to feed glue through glue barrel. Excessive force will damage glue gun. Put down nozzle after work, disconnect the power plug20W Glue Guns, 20W Mini Glue Gun, Regular Glue Gun
Ningbo Kingvos Electrical Appliance Co.,Ltd , http://www.kingvos.com