IHF series fluoroplastic lining chemical pump is one of the latest corrosion-resistant equipments in the chemical industry. When using this series of pumps, we should first know how to make it run normally, and learn to maintain such equipment well. The following is our company. The daily usage specifications of the IHF series summarized by the user:
(1) Add sufficient liquid to the pump before use. It is forbidden to start the operation without liquid or insufficient liquid storage. Otherwise, the mechanical seal will be burnt out and the pump will not work normally.
(2) Turn on the power, first jog the start switch to see if the running direction of the motor and the steering of the pump are consistent. If it does not match, it should be corrected immediately. Reverse rotation is strictly prohibited.
(3) The unit is running for 5-10 minutes. If there is no abnormality, it can be put into operation.
(4) When shutting down, the outlet gate valve should be closed first, and then the power supply should be turned off.
(5) Regularly add high-quality calcium-based grease to the bearing housing to replace the consumable parts.
(6) When the machine is not used for a long time, the flow path inside the pump should be cleaned.